Material and workloadMain resultReference comparisonStatus and boundary
Diamond Si, 8 atoms, PBE/GTH-q4, 25 Ha, 6×6×6a₀ = 5.460859 Å, B₀ = 88.306 GPa, B₀′ = 4.3052, Δ = 1.942 meV/atomAll-electron PBE: lattice 0.166%, bulk modulus 0.232%, and B₀′ 0.153% relative errorVerified for this bulk-Si EOS workload. Broader chemistry and MLX-versus-QE PWscf parity remain proof-level or diagnostic.
Diamond Si frozen-density bands, Γ-X-W-K-Γ-LIndirect gap 0.578 eV, valence width 11.959 eVPublished PBE/GTH ordering and high-symmetry energies; PBE gap is not compared with the experimental 1.12 eV gapAccepted band-path validation from a converged 6×6×6 density; not a general band-structure certification.
Diamond C, 8 atoms, PBE/GTH-q4, 40 Ha, 6×6×6, 7 volumesa₀ = 3.574441 Å, B₀ = 438.100 GPa, Δ = 1.268 meV/atomAll-electron PBE: lattice 0.075% and bulk modulus 1.080% relative errorVerified for the accepted 40 Ha workload. A 40→50 Ha central three-volume screen changed the curve by 0.438 meV/atom; no full 50 Ha curve is required.
Rock-salt MgO, 8 atoms, PBE, Mg-q2/O-q6, 70 Ha, 6×6×6, 7 volumesa₀ = 4.259503 Å, B₀ = 146.914 GPa, Δ = 1.060 meV/atomAll-electron PBE: lattice 0.123% and bulk modulus 1.387% relative errorCore EOS properties validated. The strict whole-report gate remains failed because B₀′ = 3.39995 differs from 4.09093 by 16.89%, above the locked 15% threshold; this is retained as a likely Mg-q2 transferability limit.
MgO periodic forces at the accepted EOS cell21 of 24 atom/axis comparisons pass 1e-4 Ha/bohr; maximum deviation 2.246e-4 Ha/bohrAnalytic force versus 48 reconverged ±0.01 bohr SCFsAccepted with a known float32 total-energy precision limit. The three failures are O 6-x and O 7-y/z; the threshold was not weakened.

The compact reference bundles are committed under src/mlx_atomistic/benchmarks/data/; tests lock the fit and completion semantics. Raw SCF, EOS, band, and force reports remain under gitignored results/. Quantum ESPRESSO and CP2K are reference families only and are not installed, imported, or executed by the MLX runtime or routine CI.